
Operational Permitsĭownload the Operational Permit Application and Fees (PDF). Chemical Suppression SystemĬhemical Fire Suppression Systems may require up to 30 days for review and permit issuance.

The toilet shall be on a remote portion of the sprinkler system or the system shall be designed as a loop so that water moves through a majority of the fire sprinkler system piping when the toilet is flushed. Passive purge fire sprinkler systems serve a single toilet in addition to fire sprinklers. Residential Fire Sprinkler Systems may require up to 30 days for review and permit issuance. Owners Information Certificate (page 8)Ĭommercial/Industrial Fire Sprinkler Systems may require up to 30 days for review and permit issuance.1 set of sprinkler system drawings compliant with NFPA 13, Chapter 22 (2018).Commercial/Industrial Fire Sprinkler Systems Underground Fire Lines may require up to 30 days for review and permit issuance. 1 sets of underground line drawings compliant with National Fire Protection Association (NFPA) 24, Chapter 4 (2019).

The Notice to Property Owner (pages 5 and 6 of the application packet) should be completed only when work is to be completed by an owner-builder who is not a licensed contractor. Incomplete applications will not be processed. A separate permit must be obtained for each type of system. Please ensure that application is complete and submittals contain the information required below. See instructions for the correct pages of the packet. Completed application packets may be filled out online and emailed to Application PacketĪll permit applications (excluding operational permits) use the Fire Permit Application Packet (PDF). Plan reviews and permit issuance will occur through Paso Robles Fire and Emergency Services.
